Blink codes for System-based Maestro devices
Blink Codes for System-based Maestro Devices
Maestro Dimmers/Switches/Keypads Blink Codes
NOTE: Indicator lights are numerically ordered from bottom to top.
Example: Device indicator light "1" is the bottom LED, indicator light 7 is the top LED.
Symptom:
- IL’s 1 and 7 are flashing.
Cause:
- Over Voltage Detected.
Action:
- Verify that the control is set correctly for the load.
- Check the Phase-Select Mode setting.
Symptom:
- Bottom three IL’s (1,2, and 3) are flashing.
Cause:
- Shorted FET Detected.
- Wiring error. Product may be permanently damaged.
Action:
- Check wiring to be sure it matches the installation instructions and wiring diagrams.
Symptom:
- All IL’s are flashing.
Cause :
- Over Current Detected.
Action:
- Check Phase-Select Mode setting.
- Verify that no bulbs are blown out.
- Verify that product is wired properly.
- Cycle power to the unit using the FASS switch to reset.
- If using LED or CFL bulbs, verify that they are Lutron compatible bulbs, please visit www.lutron.com/ledbulbs.
Symptom:
- Middle IL is flashing.
Cause:
- Over Temperature Detected.
- Load may exceed maximum load rating.
- Ambient temperature may exceed maximum product rating.
Action:
- Cycle power to the unit using the FASS switch to reset.
- Ensure the load is within the controls load capacity. If ganged, refer to pages 7-10 in the "RadioRA Maestro Local Controls SPEC" or pages 6-7 in the "HomeWorks Designer RF Maestro Controls SPEC"
Symptom:
- IL’s 3 and 7 are flashing
Cause:
- Line/Load Miswire Detected.
Action:
- Swap wires on Black and Brass screw terminals.
Symptom:
- Lights do not turn ON/OFF from keypad or from other remote devices.
Cause:
- Improper Programming.
- Out of RF Range.
Action:
- Refer to the Software or Lutron App for Ra2 Select to ensure proper programming.
- Reposition to be within 30ft (9m) of a RF Signal Repeater.
Symptom:
- Load is OFF and there are no indicator lights on the dimmer.
Cause:
- Power Not Present.
- Load is not installed or connected. Dimmer MUST have a load to operate.
Action:
- Circuit breaker OFF or tripped.
- FASS is in the OFF position. Move FASS to the ON position by pushing it back in.
- Check wiring to be sure it matches installation and wiring diagrams.
Symptom:
- Dimmer IL’s are ON but load cannot be turned ON and/or cannot be turned OFF.
Cause:
- Wiring Error.
- Lamps Burned Out or Not Installed.
Action:
- Check wiring to be sure it matches installation instructions and wiring diagrams.
- Replace or Install Lamps.
SeeTouch Keypads
Symptom:
- LEDs on a keypad don’t light up when a button is pressed.
Cause:
- Power not present at keypad.
- Incorrect Wiring.
Action:
- Circuit breaker OFF. Turn ON breaker.
- Wire the keypad according to the Installation section.
Symptom:
- All LEDs on the keypad flash when a button is pressed.
Cause:
- The keypad is in the Factory Settings mode and has not been configured to work in a system.
Action:
- Refer to the programming software and ensure the device is assigned to that keypad.
- Perform a transfer and make sure it is successful.
SeeTouch Hybrid Keypads
Symptom:
- All LEDs on the Hybrid Keypad flash when any button is pressed.
Cause:
- The Hybrid Keypad is in Factory Settings mode and has not been configured to work in a system.
Action:
- Follow the steps in the system Setup Guide to program the Hybrid Keypad.
¿Fue útil este artículo?